High-Volume Ice Production Engineered for Peak-Demand Foodservice
Built for Venues Where Ice Demand Never Stops at Normal Volume
Hotels running multiple banquets, hospitals with round-the-clock patient service, and large-scale catering operations share a common problem: their ice demand at peak hours can exceed what a standard-capacity machine was ever designed to deliver. The Large Capacity Commercial Ice Maker is purpose-built around this reality, with production ratings reaching into the 1500-2000 lb per 24-hour range so a single unit — or a paired installation — can absorb the demand spikes that would force a standard machine into constant catch-up mode. Rather than scaling a small-capacity design upward, the internal evaporator plate, water distribution system, and compressor circuit are engineered from the outset for sustained high-volume output.
At this production scale, a single compressor circuit becomes a liability if it fails, so our large-capacity models are available with dual independent refrigeration circuits feeding separate sections of the same evaporator plate. If one circuit requires service, the second continues producing ice at roughly half capacity rather than the unit going fully offline — a critical distinction for hospitals and hotels where an ice outage during full occupancy is not an acceptable operational risk. The water distribution system is similarly reinforced with a higher-flow pump and wider distribution tubes to keep freeze cycles consistent across the larger plate surface, preventing the uneven ice formation that can occur when a small-machine water system is simply scaled up without redesign.
Because large-capacity machines are typically paired with oversized storage bins to buffer between production and peak service hours, the head unit is engineered to interface with high-volume bins and can be specified with remote condensing to keep heat rejection out of the mechanical room entirely. This is the format specified for central kitchens supplying multiple outlets, large-scale catering commissaries preparing for banquet volume, and hospital central supply departments where a single point of ice production must reliably serve an entire facility without interruption during the highest-demand hours of the day.
Facilities operating at this production scale typically integrate the ice machine into a broader preventive maintenance program, and our control system supports that by logging compressor run-time and cycle data that service teams can review remotely rather than waiting for a failure to trigger a site visit. Given the capital investment represented by a high-capacity installation, we also offer extended warranty packages and priority parts availability for large-capacity models, recognizing that an unplanned outage at this scale affects an entire facility's ice supply rather than a single station. Site planning for these units typically includes confirming adequate electrical service, water supply capacity, and drain sizing well before installation, since the infrastructure requirements at 1500-2000 lbs per day scale are substantially greater than a standard kitchen ice maker. Facilities that plan this infrastructure correctly from the outset typically avoid the costly retrofits that come from underestimating water, drain, or electrical capacity once a high-volume unit is already installed and running at full demand. We recommend engaging our technical team during the design phase of any new build or major renovation so utility rough-ins are sized correctly for the selected capacity from day one.
| Ice Production | 1500 / 1800 / 2000 lbs per 24h |
| Refrigeration Circuits | Dual Independent Circuits |
| Compatible Bin | 60in+ High-Capacity Bin |
| Cube Type | Full Dice / Half Dice |
| Cooling Type | Air, Water, or Remote Condenser |
| Housing Material | Heavy-Gauge Stainless Steel |
| Voltage | 208-230V, 3-Phase |
Independent refrigeration circuits feed separate zones of the evaporator plate, so a single-circuit service event reduces output rather than halting ice production entirely during peak demand.
Absorbs simultaneous event demand across multiple function spaces from one production point.
Dual-circuit reliability keeps ice available continuously for round-the-clock patient service.
Hicon products are well sold to more than fifty countries and regions, such as the USA, Germany, Canada, Japan, Korea, the UK, France, Spain, Mexico, etc.
Since 1972, over 50 years experience in refrigeration industry, specialized in household refrigeration, commercial display refrigerator electrical appliances.
Vertically integrated manufacture, global production bases, center of industrial for hightech manufacturer & refrigeration equipment.
Sheet metal manufacturing In house, 2 assembly lines for Refrigerators, 1 freezer assembly lines, 4 ice-maker assembly lines.
We have a strong R&D team, and we can develop and produce products according to the drawings or samples the customers offered.
Products are well sold to more than fifty countries and regions, such as the USA, Japan, Canada, Spain, France and Italy.
Running several standard machines to reach high volume multiplies maintenance points and floor space; our Single High-Output Platform reaches the same volume from one engineered production point.
The Dual-Circuit Design means partial redundancy is built in from the factory, rather than relying on a second full machine as a backup during service events.
T/T, L/C at Sight, Bank GuaranteeStructured terms for large capital equipment orders
FOB Ningbo / ShanghaiReinforced crating for heavy-duty export
Built-to-order production30-40 day lead time
The unit continues operating on the remaining circuit at reduced output rather than shutting down completely.
Yes, remote condensing is available to move heat rejection outside the mechanical room.
High-capacity models are designed to pair with 60-inch or larger storage bins for adequate buffering.
Yes, models in this capacity range require 208-230V three-phase electrical service.
The evaporator, water system, and compressor circuits are engineered specifically for sustained high-volume output, not just scaled up from a smaller design.
Yes, paired installations are common for facilities requiring redundancy beyond the dual-circuit design.
| MOQ | 10 Sets |
| Lead Time | 30-40 Days |
| Certifications | CE, ETL, NSF, RoHS |
Contact our sales team today to discuss your requirements.